Customized Single Button Medical Membrane Switch With Tactile Feedback

Customized Single Button Medical Membrane Switch With Tactile Feedback

Product Details:

Place of Origin: DongGuan of China
Brand Name: GC Technology
Certification: ISO9001,SGS,ROHS,REACH,UL
Model Number: 042-032

Payment & Shipping Terms:

Minimum Order Quantity: 200 pcs
Price: communication
Packaging Details: PE bags first and Foam in Carton and etc
Delivery Time: 4-5 days for Samples making ;10-15 days for Batch goods
Payment Terms: Western Union, T/T,PAYPAL
Supply Ability: 20000 +pcs +a Month
Get Best Price Contact Now

Detail Information

Material: Polyester Or Polycarbonate Or Others Color: Pantone, RAL CMYK ,RGB
Pitch Of Connect: 1.0MM , Adhesive: 3M467 200MP Adheisve Or Others
Button Type: Embossing Metal Dome Connector Type: ZIF Contacts
PN: Membrane Switch ,Membrane Keypad ,keyboard ,overlay Circuit Options: Silver Flex Circuit
Application: Medical Device LED Color: Green
Highlight:

Customized Medical Membrane Switch

,

Single Button Medical Membrane Switch

,

Tactile Feedback Custom Membrane Switches

Product Description

 
Custom Single button Medical Membrane Switches with Tactile Feedback

 

 

A single medical membrane switch is a type of input device commonly used in medical equipment, devices, and instrumentation. These switches are designed to be durable, easy to clean, and resistant to the environments found in medical settings.

Key features of single medical membrane switches:

  • Consist of a single, sealed membrane-based switch assembly
  • Constructed with medical-grade materials that can withstand frequent cleaning and disinfection
  • Provide tactile feedback when pressed, but have a smooth, sealed surface
  • Designed to be flush-mounted or integrated directly into medical equipment
  • Resistant to liquids, dust, and other contaminants that could interfere with operation
  • Highly reliable and long-lasting, with millions of guaranteed actuations
  • Customizable in terms of size, shape, graphics, and actuation force
  • Commonly used for control panels, diagnostic equipment, patient monitoring devices, etc.

The sealed, single-switch design of these membrane switches makes them well-suited for medical applications where infection control, ease of cleaning, and resistance to fluids/chemicals are critical requirements. Their durability and reliability are important for mission-critical medical devices. The customizable nature also allows them to be integrated seamlessly into medical equipment.

In summary, single medical membrane switches provide a hygienic, robust, and customizable input solution for a wide range of medical devices and instrumentation. Their specialized design makes them an ideal choice for healthcare applications.

 

 Descriptions :

 

Overlay material ---For front or face overlay
Polyester Polycarbonate

1 Highly versatile for embossing
2 Highly resistant for chemicals
3 Better durability
4 For internal and external use

1 wide range of the surface finishes and thicknesses
2 More cost-effective
3 For internal and external use
4 many Lexan label choose

Embossing --- Graphic overlay or up circuit can be embossed in order to insert metal stainless steel domes for good tactile when press .Leave space for mechanical keys and provide tactile indications
Pedestal embossing Rim embossing Pillow embossing Dim embossing
Windows or LCD --- For display functions
Printed colors windows such like red ,black and so on Transparent finishes windows
Keys
Tactile Keys :witch metal domes or Poly domes ,Metal dome with different diameter and pressure kinds Non-tactile keys: printed silver spot on the circuit
LEDs ---Miniature LEDs ,LED colors :white ,Green ,Red ,Blue ,Yellow ,Orange and others
EL and Sensors or inductors --- EL can be light any place where where you like ,and sensors can be used as LEDs
Cables --- is extension of circuit and communication with your device
Screen printing conductive silver cable Copper plated cable /Polyimide or FPC PCB cable
Types of connector --- 1 Zero insertion force(ZIF) with 0.5MM ,1.0MM,1.25MM pitch ;2 Female connector with 2.54MM pitch; 3 Male connector
Shielding --- For protection function
Gasket seal/Waterproof :protect the conductors against from the humidity and splashes EMI/RFI/ESD Shielding: use an Aluminum foil shielding /clear ITO electrical conductive polyester to protect
Rear Adhesive --- Mostly use the 3M double-side mounting glue brand of USA. Also accepted others such like Lohmann and others
Back plate --- Use in Aluminum ,Polycarbonate ,Acrylic Or PMMA
Matching color --- PMS or RAL Is best ,CMYK or RGB also can be ok if you can supply PMS Or RAL
Standard Tolerances :+/-0.2MM

 
 
 

Performance Index

Environmental Operating Temperature -40°C to +80°C (-40°to 176°F)
  Storage Temperature -40°C to +85°C (-40°to 185°F)
  Humidity 40°C, 90% to 95% for 240 hours
  Vibration 20G's max.
Mechanical Actuation Force Non-tactile 60g to 300g (2oz to 10oz)
    Tactile 150g to 400g (6oz to 14oz)
  Switch Stroke Non-tactile 0.1 to 0.5mm
  Life Expectancy Tactile 0.6 to 1.5mm
    Non-tactile >5 million actuations
    Tactile >1 million actuations
Electrical Operating Voltage 35 volts maximum
  Operating Current 10 micro amps to 100 milliamps, resistive
  Operating Power 1 watt maximum
  Circuit Resistance 10 ohms to 500 ohms, dependent on size and layout
  Insulation Resistance 100M ohms at 100V DC
  Dielectric Withstand >250 VRMs (50-60Hz 1 minute)
  Contact Bounce ≤ 5 milliseconds
 

 

 

 

 
 
 
Other photo show :
Customized Single Button Medical Membrane Switch With Tactile Feedback 0Customized Single Button Medical Membrane Switch With Tactile Feedback 1Customized Single Button Medical Membrane Switch With Tactile Feedback 2Customized Single Button Medical Membrane Switch With Tactile Feedback 3
 

 

 

 

What are the key advantages of single medical membrane switches over other input options for medical devices?

 

There are several key advantages that single medical membrane switches offer over other input options for medical devices:

  1. Infection Control and Hygiene:
  • The sealed, single-switch design with no gaps or crevices prevents the accumulation of dirt, dust, or fluids.
  • The smooth, continuous surface can be easily wiped down and disinfected, reducing the risk of cross-contamination.
  • This is critical for medical equipment used in sterile environments or near patients.
  1. Durability and Reliability:
  • Medical membrane switches are engineered to withstand frequent cleaning with harsh chemicals and disinfectants.
  • They are tested to millions of actuations, ensuring long-lasting performance in demanding medical applications.
  • The lack of moving parts makes them more resistant to wear and tear compared to mechanical switches.
  1. Customizability:
  • Single medical membrane switches can be customized in terms of size, shape, graphics, and actuation force.

 

 

Want to Know more details about this product
I am interested in Customized Single Button Medical Membrane Switch With Tactile Feedback could you send me more details such as type, size, quantity, material, etc.
Thanks!
Waiting for your reply.